AEE/Chapter 9/Read MCQs
๐Ÿ“– Back to Study Notes
9

Chapter 9 ยท MCQ Read Mode

Power Systems and Devices

AEEE09ยท68 Total MCQs
Question 1 of 68Power Plant

The correct order of stages in a power system is:

ADistribution โ†’ Transmission โ†’ Generation
BGeneration โ†’ Transmission โ†’ Distribution
CTransmission โ†’ Generation โ†’ Distribution
DGeneration โ†’ Distribution โ†’ Transmission
Answer is hidden
Question 2 of 68Power Plant

A thermal power plant primarily converts which form of energy to drive its turbine?

AWind kinetic energy
BHeat energy from burning fuel, via steam
CSolar radiation directly
DTidal potential energy
Answer is hidden
Question 3 of 68Power Plant

Which turbine type is commonly used in hydro power plants with high head?

APelton wheel
BWind turbine blade
CGas turbine
DSteam reheater
Answer is hidden
Question 4 of 68Power Plant

A solar photovoltaic (PV) system generates electricity by:

ABurning solar-collected fuel
BDirectly converting sunlight to DC electricity via the photovoltaic effect
CDriving a steam turbine
DChemical combustion of hydrogen
Answer is hidden
Question 5 of 68Power Plant

A fuel cell generates electricity through:

AMechanical rotation of a turbine
BAn electrochemical reaction converting chemical energy directly to DC electricity
CNuclear fission
DWind kinetic energy
Answer is hidden
Question 6 of 68Power Plant

Geothermal power plants generate electricity using:

AHeat from the Earth's interior
BTidal currents
CNuclear fission
DWind kinetic energy
Answer is hidden
Question 7 of 68Power Plant

Tidal power generation is most similar in operating principle to:

ASolar PV generation
BHydro power generation
CFuel cell generation
DNuclear generation
Answer is hidden
Question 8 of 68Power Plant

Energy storage systems in a power grid are primarily used to:

AIncrease transmission voltage
BBalance supply and demand, especially with intermittent renewables
CReplace the need for transmission lines
DGenerate reactive power only
Answer is hidden
Question 9 of 68Power Plant

Nuclear power plants generate steam using heat produced by:

AChemical combustion
BControlled nuclear fission
CSolar concentration
DGeothermal reservoirs
Answer is hidden
Question 10 of 68Power Plant

Generating stations are typically located far from load centers mainly because of:

AFuel/resource availability and environmental considerations
BLower construction cost near the load only
CLegal requirements to be underground
DAvoiding the need for transmission lines
Answer is hidden
Question 11 of 68Transmission & Distribution of Electrical Power

AC is preferred over DC for most power transmission mainly because:

AAC has lower resistance
BAC voltage can easily be stepped up/down using transformers
CDC cannot be generated economically
DAC requires no insulation
Answer is hidden
Question 12 of 68Transmission & Distribution of Electrical Power

Kelvin's Law for economical conductor size states that the most economical size is where:

AConductor cost is minimum regardless of losses
BAnnual cost of energy loss equals annual interest and depreciation on capital cost
CCurrent density is maximum
DInsulation cost is zero
Answer is hidden
Question 13 of 68Transmission & Distribution of Electrical Power

ACSR conductors combine aluminium with a steel core primarily to provide:

ABetter insulation
BMechanical strength while keeping good conductivity
CLower cost only
DCorona reduction
Answer is hidden
Question 14 of 68Transmission & Distribution of Electrical Power

Corona discharge on a transmission line occurs when:

AThe conductor is too thick
BThe surface voltage gradient of the conductor exceeds the breakdown value of surrounding air
CThe line is underground
DThe load factor is high
Answer is hidden
Question 15 of 68Transmission & Distribution of Electrical Power

A radial distribution system is characterized by:

AHighest reliability of all schemes
BPower flowing in only one direction from a single source, least reliable
CMultiple interconnected sources
DNo feeders required
Answer is hidden
Question 16 of 68Transmission & Distribution of Electrical Power

The load factor of a power system is defined as:

AMaximum demand / connected load
BAverage load / maximum load
CConnected load / average load
DPeak load / installed capacity
Answer is hidden
Question 17 of 68Transmission & Distribution of Electrical Power

Demand factor is defined as:

AAverage load / maximum load
BMaximum demand / connected load
CConnected load / maximum demand
DEnergy consumed / time
Answer is hidden
Question 18 of 68Transmission & Distribution of Electrical Power

A load duration curve differs from a load curve in that it:

AShows load vs time chronologically
BShows the same load data rearranged in descending order of magnitude
COnly applies to renewable sources
DCannot be used to estimate energy consumed
Answer is hidden
Question 19 of 68Transmission & Distribution of Electrical Power

Interference between power lines and nearby communication lines is primarily mitigated using:

AHigher transmission voltage
BAdequate separation/shielding and careful routing
CRemoving all insulators
DIncreasing the demand factor
Answer is hidden
Question 20 of 68Transmission & Distribution of Electrical Power

Power Line Carrier Communication (PLCC) uses:

AA separate fibre-optic cable
BThe power transmission line itself to carry high-frequency signals
CSatellite links only
DUnderground telephone cables exclusively
Answer is hidden
Question 21 of 68Protection & Control of Electrical Power System

The primary goal of power system protection is to:

AMaximize fault current
BDetect faults quickly and isolate only the faulted section
CIncrease transmission voltage
DEliminate the need for relays
Answer is hidden
Question 22 of 68Protection & Control of Electrical Power System

A fuse protects a circuit by:

AAutomatically resetting after tripping
BMelting and breaking the circuit when current exceeds a rated value
CMeasuring impedance to the fault
DSensing earth faults only
Answer is hidden
Question 23 of 68Protection & Control of Electrical Power System

SFโ‚† circuit breakers are valued for their:

APoor dielectric strength
BExcellent arc-quenching and dielectric properties of sulphur hexafluoride gas
CUse of transformer oil
DVery low switching capacity
Answer is hidden
Question 24 of 68Protection & Control of Electrical Power System

A differential relay operates based on:

AAbsolute current magnitude only
BThe difference between currents entering and leaving a protected zone
CVoltage magnitude only
DFrequency deviation
Answer is hidden
Question 25 of 68Protection & Control of Electrical Power System

A distance (impedance) relay is typically used to protect:

ATransformers
BTransmission lines
CFuses
DCapacitor banks only
Answer is hidden
Question 26 of 68Protection & Control of Electrical Power System

The main purpose of earthing (grounding) equipment is to:

AIncrease system voltage
BLimit touch/step potential and provide a fault-current path
CReduce transmission losses
DEliminate the need for circuit breakers
Answer is hidden
Question 27 of 68Protection & Control of Electrical Power System

Surge protection devices are designed to:

AIncrease transient overvoltages
BDivert transient overvoltages safely to ground
CReplace circuit breakers
DOperate only during normal load conditions
Answer is hidden
Question 28 of 68Protection & Control of Electrical Power System

Load shedding differs from a blackout in that load shedding is:

AUncontrolled and total
BA deliberate, controlled disconnection to prevent wider collapse
COnly used during faults
DIllegal in most countries
Answer is hidden
Question 29 of 68Protection & Control of Electrical Power System

SCADA systems are primarily used for:

APhysical construction of transmission towers
BRemote real-time monitoring and control of substations/field equipment
CGenerating electrical power directly
DBilling customers
Answer is hidden
Question 30 of 68Protection & Control of Electrical Power System

A Smart Grid is distinguished from a conventional grid mainly by its use of:

AOne-way analog communication only
BTwo-way digital communication, automation, and distributed intelligence
CManual switching only
DExclusively DC transmission
Answer is hidden
Question 31 of 68Residential & Industrial Electrification

Service mains refer to the connection between:

ATwo consumer premises
BThe utility's distribution line and the consumer's premises/meter
CGeneration and transmission
DTransmission and sub-transmission
Answer is hidden
Question 32 of 68Residential & Industrial Electrification

The most common wiring method in modern residential buildings is:

ACleat wiring
BCasing-capping wiring
CConcealed conduit wiring
DBare open wiring
Answer is hidden
Question 33 of 68Residential & Industrial Electrification

An electrical layout drawing for a building primarily shows:

AOnly the structural beams
BPositions of points, wiring runs, and the distribution board on the floor plan
CLoad flow analysis results
DThe generation mix of the utility
Answer is hidden
Question 34 of 68Residential & Industrial Electrification

Load estimation for a distribution board applies:

ANo correction factors
BDiversity/demand factors to the total connected load
COnly the maximum-demand tariff
DCorona correction
Answer is hidden
Question 35 of 68Residential & Industrial Electrification

Industrial motor loads typically require which type of supply for larger ratings?

ASingle-phase only
BThree-phase supply
CDC supply only
DNo electrical supply, only mechanical
Answer is hidden
Question 36 of 68Residential & Industrial Electrification

Motor starting current is typically:

ALower than full-load current
BSeveral times the full-load current
CZero
DEqual to no-load current
Answer is hidden
Question 37 of 68Residential & Industrial Electrification

A maximum-demand tariff bills the consumer based on:

AOnly energy consumed (kWh)
BThe highest demand (kW/kVA) recorded during the billing period, plus energy used
CTime of day only
DNumber of appliances installed
Answer is hidden
Question 38 of 68Residential & Industrial Electrification

Poor power factor in an industrial load typically results in:

ALower electricity bills
BTariff penalties and increased line losses
CNo effect on the utility
DAutomatic power factor correction
Answer is hidden
Question 39 of 68Residential & Industrial Electrification

Which of the following is an energy conservation measure in buildings?

AIncreasing incandescent lighting use
BPower factor correction and use of efficient (LED) lighting
CRemoving all protective devices
DIgnoring load scheduling
Answer is hidden
Question 40 of 68Residential & Industrial Electrification

A ring distribution circuit within a building is chosen mainly for:

ALower cost than radial only
BBetter load sharing and improved reliability
CSimplicity in small residential wiring
DEliminating the need for a distribution board
Answer is hidden
Question 41 of 68Power Electronics

A Silicon Controlled Rectifier (SCR) conducts current in:

ABoth directions equally
BOne direction only, once triggered
CNeither direction
DOnly during reverse bias
Answer is hidden
Question 42 of 68Power Electronics

An SCR is turned OFF (commutated) when:

AA negative gate pulse is applied
BIts current falls below the holding current
CThe supply voltage is doubled
DIt is forward-biased further
Answer is hidden
Question 43 of 68Power Electronics

A diac is best described as a:

AUnidirectional, 3-terminal gated device
BBidirectional, 2-terminal, gateless breakover device
CPurely resistive element
DVoltage regulator IC
Answer is hidden
Question 44 of 68Power Electronics

A triac is functionally equivalent to:

AA single SCR
BTwo SCRs connected in antiparallel with a common gate
CA diode bridge
DA simple resistor
Answer is hidden
Question 45 of 68Power Electronics

Forced commutation of a thyristor is typically required in:

AAC circuits, where current naturally crosses zero
BDC circuits, where current does not naturally fall to zero
CCircuits with no load
DCircuits using only diacs
Answer is hidden
Question 46 of 68Power Electronics

An SMPS achieves higher efficiency than a linear regulator mainly because:

AIt uses larger transformers
BIts switching device operates mostly in cutoff/saturation, minimizing power dissipation
CIt avoids using any semiconductor devices
DIt operates only at very low voltages
Answer is hidden
Question 47 of 68Power Electronics

A buck converter is a type of DC-DC converter that:

ASteps up the output voltage
BSteps down the output voltage
CConverts DC to AC
DConverts AC to DC
Answer is hidden
Question 48 of 68Power Electronics

An inverter is a power electronic device that converts:

AAC to DC
BDC to AC
CAC to AC at a different frequency only
DOne DC voltage to another DC voltage
Answer is hidden
Question 49 of 68Power Electronics

An Uninterrupted Power Supply (UPS) provides continuous power to a load primarily using:

AA diesel generator only
BA battery and inverter
CA step-down transformer only
DA capacitor bank alone
Answer is hidden
Question 50 of 68Power Electronics

Which device is commonly used to trigger a triac into conduction?

AA diac
BAn SCR
CAn op-amp
DA Zener diode alone
Answer is hidden
Question 51 of 68Power System Analysis

Which fault type produces the highest fault current, used to rate circuit breakers?

ALine-to-ground fault
BLine-to-line fault
CSymmetrical three-phase fault
DDouble line-to-ground fault
Answer is hidden
Question 52 of 68Power System Analysis

The most common type of fault occurring on a power system is:

AThree-phase fault
BLine-to-ground fault
CLine-to-line fault
DDouble line-to-ground fault
Answer is hidden
Question 53 of 68Power System Analysis

Unsymmetrical (unbalanced) faults are analyzed using:

APer-unit system alone
BSymmetrical component (sequence network) analysis
CLoad flow analysis only
DEqual area criterion
Answer is hidden
Question 54 of 68Power System Analysis

In load flow analysis, the slack (swing) bus is characterized by:

AKnown P and Q, unknown |V| and angle
BKnown |V| and angle, unknown P and Q
CKnown P and |V| only
DNo physical meaning
Answer is hidden
Question 55 of 68Power System Analysis

A PV bus in load flow analysis has known:

AReal power P and reactive power Q
BReal power P and voltage magnitude |V|
CVoltage angle only
DNothing is known
Answer is hidden
Question 56 of 68Power System Analysis

Compared to the Gauss-Seidel method, the Newton-Raphson method for load flow offers:

ASlower, linear convergence
BFaster, quadratic convergence, preferred for large systems
CNo convergence at all
DConvergence only for small systems
Answer is hidden
Question 57 of 68Power System Analysis

Transient stability of a power system refers to its ability to:

ARemain synchronized under slow, small load changes
BRemain synchronized following a large, sudden disturbance
COperate at unity power factor always
DAvoid all faults permanently
Answer is hidden
Question 58 of 68Power System Analysis

The equal area criterion is used to assess:

ALoad flow convergence
BTransient stability of a single-machine system graphically
CFault current magnitude
DTariff structures
Answer is hidden
Question 59 of 68Power System Analysis

The swing equation describes:

AVoltage regulation of a transformer
BThe rotor angle dynamics of a synchronous machine following a disturbance
CThe load duration curve
DThe economic choice of conductor size
Answer is hidden
Question 60 of 68Power System Analysis

Dynamic stability studies specifically account for the effect of:

AConductor material
BControl systems such as governors and AVRs over a longer time period
CCorona discharge
DTariff rate structures
Answer is hidden
Question 61 of 68Information Theory & Signals

The Fourier Transform is used to:

AConvert a signal from the time domain to the frequency domain
BConvert a signal from the frequency domain to the time domain
CCompress digital signals
DEncrypt data transmissions
Answer is hidden
Question 62 of 68Information Theory & Signals

When a square wave is applied to an integrator op-amp circuit, the output is:

ASquare wave
BSine wave
CTriangle wave
DSawtooth wave
Answer is hidden
Question 63 of 68Information Theory & Signals

The Z-transform is primarily used for:

AAnalysing continuous-time signals
BAnalysing discrete-time signals and systems
CImage compression
DFrequency modulation
Answer is hidden
Question 64 of 68Information Theory & Signals

Interleaving in digital communications provides what type of diversity?

ATime diversity
BFrequency diversity
CSpace diversity
DPolarization diversity
Answer is hidden
Question 65 of 68Information Theory & Signals

In FDM, increasing the modulation index results in:

ADecreased bandwidth requirements
BIncreased bandwidth requirements
CNo change in bandwidth
DIncreased signal-to-noise ratio without bandwidth change
Answer is hidden
Question 66 of 68Information Theory & Signals

Adding zeros to the end of a discrete signal before taking its DFT is called:

AZero Padding
BWindowing
CDecimation
DInterpolation
Answer is hidden
Question 67 of 68Information Theory & Signals

In TDM (Time Division Multiplexing), the component essential for recovering individual channels at the receiver is:

AEqualizer
BFrame synchronization
CBandwidth filter
DDemodulator
Answer is hidden
Question 68 of 68Information Theory & Signals

In a common-collector (emitter follower) BJT amplifier, the phase relationship between input and output is:

A180 degrees (inverted)
B90 degrees
C0 degrees (in phase)
D45 degrees
Answer is hidden
โ† PREVIOUS CHAPTERCh 8: Communication Systems NEXT CHAPTER โ†’Ch 10: Project Planning, Design and Implementation